I recently made the switch from the marlin-based stock firmware on my anycubic kobra 2, to klipper. I didn’t have issues with bed levelling or first layer on the stock firmware, but I’m having significant issues running klipper. The bed is uneven, the probed mesh shows a deviation of 0.197mm, it was the same when running stock FW+octoprint.

But it seemed to be correcting just fine for this on the stock FW. I got a consistent decent first layer across the entire bed.

With klipper, it’s absolutely impossible to get it to correct for this unevenness. Half the bed will get perfect first layer, but then the second half is either way too squished or hardly connecting to the bed. And it’s causing further issues as it’s also hitting the print when moving, despite having Z-hop of 0.3mm for travel moves.

What the hell is going on? How do I fix this?

  • Grippler@feddit.dkOP
    link
    fedilink
    English
    arrow-up
    0
    ·
    5 months ago

    [gcode_macro PRINT_BEGIN] description: Begin printing with nozzle wipe gcode: M300 P500 % set BED_TEMP = params.BED_TEMPdefault(60)|float % % set EXTRUDER_TEMP = params.EXTRUDER_TEMPdefault(210)|float % BED_MESH_PROFILE LOAD=default M104 S{EXTRUDER_TEMP} M140 S{BED_TEMP} {% if printer.toolhead.homed_axes != “xyz” %} G28 {% endif %} #BED_TILT_CALIBRATE G1 X80 Y240 Z5.0 F3000 ; position nozzle right next to wipe pad M190 S{BED_TEMP} M109 S{EXTRUDER_TEMP} M300 P500 G4 P50 M300 P500 S1500 G1 Z-0.1 ; lower nozzle before wiping G1 X90 F500 ; wipe nozzle across pad in X direction G1 Y235 F500 ; wipe nozze in Y direction G1 Z3 ; lift nozzle to 3mm G1 X90 Y-3 F6000 ; move nozze to front-left center of bed for purging G1 Z0.28 ; lower nozzle to 0.28mm G1 X120 E25 F200 ; extrude 25mm of filament in a 40mm line G92 E0 ; reset extruder position G1 E-1 F2100 ; quickly retract filament 3mm G1 X135 F10000 ; quickly move away from purge
    G92 E0

      • Grippler@feddit.dkOP
        link
        fedilink
        English
        arrow-up
        0
        ·
        5 months ago

        Sure

        [bed_mesh] speed: 150 horizontal_move_z: 5 mesh_min: 25, 17 mesh_max: 220, 200 algorithm: bicubic bicubic_tension: 0.5 probe_count: 6, 6

        • morbidcactus@lemmy.ca
          link
          fedilink
          English
          arrow-up
          1
          ·
          edit-2
          5 months ago

          What type of probe and what’s the config on it?

          [probe]
          pin: PC14
          x_offset: 23
          y_offset: 5
          #z_offset: 0.10
          speed: 20.0
          samples: 5 
          samples_result: average
          sample_retract_dist: 1.0
          #samples_tolerance: 0.010
          #samples_tolerance_retries: 10
          

          Is what I’ve got my pinda probe configured with, was playing around with sample tolerances like I have on my printer with a tap probe but I just found the inductive probe has a lot of variation, I added more samples to hopefully average out that error.

          [Bed_mesh]
          algorithm: bicubic
          fade_start: 0.6
          fade_end: 10.0
          bicubic_tension: 0.2
          faulty_region_1_max: 120.0, 74.0 
          faulty_region_1_min: 85.0, 45.0 # 103,69
          faulty_region_2_max: 125.0, 165
          faulty_region_2_min: 70, 110 # 103, 137
          horizontal_move_z: 2
          mesh_max: 228,210
          mesh_min: 24, 6
          mesh_pps: 2, 2
          probe_count: 5,5
          speed: 200 
          

          Is my mesh setup, based on a mk3s klipper config. Meshes look a little odd but I ran some bed level prints fine and just ran a full plate of abs with pretty consistent 1st layer.